TLE4998P3C E1200
Error Detection
7
Error Detection
Different error cases can be detected by the On-Board-Diagnostics (OBD) and reported
to the microcontroller. The OBD is useful only when the clamping function is enabled.
7.1
Voltages Outside the Operating Range
The output signals error conditions if VDD crosses the overvoltage threshold level.
Table 14 Overvoltage
Parameter
Symbol Limit Values
Unit
min. typ. max.
Overvoltage threshold
Output duty cycle
@ overvoltage
VDDov 16.65 17.5
CYPWMov 100 1) -
18.35 V
-
%
1) Output stays in “off” state (high ohmic)
Notes
7.2
EEPROM Error Correction
The parity method is able to correct one single bit in one EEPROM line. One other single-
bit error in another line can also be detected. As this situation is not correctable, this
status is signalled at the output pin by clamping the output value to CYPWM = 100%.
Table 15 EEPROM Error Signalling
Parameter
Symbol Limit Values
Output duty cycle
@ EEPROM error
min.
CYPWMerr 100 1)
max.
1) Output stays in “off” state (high ohmic)
Unit
%
Notes
Data Sheet
24