TLE4998P3C E1200
Signal Processing
6.5
Clamping
The clamping function is useful for splitting the output voltage range into operating range
and error ranges. If the magnetic field is outside the selected measurement range, the
output value OUT is limited to the clamping values. Any value in the error range is
interpreted as an error by the sensor counterpart.
Table 12 Clamping
Parameter
Symbol Limit Values
min. max.
Register size
CL,CH
2x7
Clamping duty cy. low
Clamping duty cy. high
Clamping quantization
steps
CYCLPWM
CYCHPWM
∆CYCxPWM
0
99.2
0.76 100
0.78
1) For CL = 0 and CH = 127 the clamping function is disabled
2) CYCLPWM< CYCHPWM mandatory
3) Quantization starts for CL at 0% and for CH at 100%
The clamping values are calculated by:
Unit
bit
%
%
%
Notes
1)
1) 2)
3)
Clamping duty cycle low (deactivated if CL=0):
CYCLPWM
=
C-----L-----⋅---3---2-
4095
Clamping duty cycle high (deactivated if CH=127):
CYCHPWM
=
(---C----H------+-----1---)----⋅---3---2---–----1-
4095