English
Language : 

ICE3AR0680JZ Datasheet, PDF (25/34 Pages) Infineon Technologies AG – Of f -Line SMPS Cur rent Mode Cont rol ler wi th integrated 800V
CoolSET®-F3R80
ICE3AR0680JZ
Electrical Characteristics
4.3.5
Control Unit
Parameter
Symbol
Limit Values
Unit Test Condition
min. typ. max.
Brownout reference voltage for
comparator C14
VBO_ref
0.80
0.90
1.00 V
Blanking time voltage lower limit for
Comparator C3
VBKC3
0.80
0.90
1.00 V
Blanking time voltage upper limit for
Comparator C11
VBKC11
4.28
4.50
4.72 V
Over Load Limit for Comparator C4
Entry Burst select High level for
Comparator C19
VFBC4
VFBC19
4.28
4.28
4.50
4.50
4.72 V
4.72 V
Entry Burst select Low level for
Comparator C20
VFBC20
0.40
0.50
0.60 V
Active Burst Mode
Entry Level for
Comparator C5
10% Pin_max
6.67% Pin_max
4.38% Pin_max
Active Burst Mode High Level for
Comparator C6a
VFB_burst1
VFB_burst2
VFB_burst3
VFBC6a
1.51
1.34
1.20
3.35
1.60
1.42
1.27
3.50
1.69 V
1.50 V
1.34 V
3.65 V
< 7 counts
8 ~ 39 counts
40 ~ 191 counts
In Active Burst Mode
Active Burst Mode Low Level for
Comparator C6b
VFBC6b
3.06
3.20
3.34 V
Active Burst Mode Level for
Comparator C13
VFBC13
3.85
4.00
4.15 V
Overvoltage Detection Limit for
Comparator C1
VVCCOVP1 19.5
20.5
21.5 V
VFBB = 5V, during soft
start
Overvoltage Detection Limit for
Comparator C2
VVCCOVP2 25.0
25.5
26.3 V
Auto-restart enable reference voltage VAE
for Comparator C9
0.25 0.40 0.45 V
Charging current for extended
blanking time
Ichg_EB
480
720
864 mA
Charging current for brownout
Thermal Shutdown1)
Hysteresis for thermal Shutdown1)
Ichg_BO
TjSD
TjSD_hys
9.0
130
-
Built-in Blanking Time for Overload
tBK
-
Protection or enter Active Burst Mode
10.0
140
50
20
10.8 mA
150 °C Controller
- °C
- ms
Timer for entry burst select
tEBS
-
1
- ms
Spike Blanking Time for Auto-Restart tSpike
-
30
- ms
Protection
1) The parameter is not subjected to production test - verified by design/characterization. The thermal shutdown
temperature refers to the junction temperature of the controller.
Note: The trend of all the voltage levels in the Control Unit is the same regarding the deviation except VVCCOVP
Version 2.1a
25
11 Jan 2012