TLE7824G Datasheet, PDF (23/53 Pages) Infineon Technologies AG – Integrated double low-side switch, high-side/LED driver, hall supply, wake-up inputs and LIN communication with embedded MCU (24kB Flash) | |||
|
◁ |
Table 7
T4
0
0
0
0
0
0
0
â¦
1
Cyclic Wake Period Settings (Stop Mode only)
T3
T2
T1
T0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
â¦
â¦
â¦
â¦
1
1
1
1
TLE7824G
SPI (Serial Peripheral Interface)
Cyclic Wake Period
Cyclic Wake âoffâ
16 ms
32 ms
48 ms
64 ms
80 ms
96 ms
⦠ms
496 ms
Table 8
T5
Window Watchdog Reset Period Settings
T4
T3
T2
T1
T0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
0
1
1
0
0
0
1
0
0
0
0
0
1
0
1
0
0
0
1
1
0
â¦
â¦
â¦
â¦
â¦
â¦
1
1
1
1
1
1
Window Watchdog
Reset Period
ânot a valid selectionâ
16 ms
32 ms
48 ms
64 ms
80 ms
96 ms
⦠ms
1008 ms
Table 9 SPI Output Data
Pos. Output Data1)
0
VCC Temperature Prewarning
1
HS-LED fail (OC / OT)
2
VINT-Fail (âactive lowâ)
3
LS1/2 (OC / OT)
4
Window Watchdog Reset
5
MON1 Logic Input Level
6
MON2 Logic Input Level
7
MON3 Logic Input Level
8
MON4 Logic Input Level
9
MON5 Logic Input Level
10
âreservedâ / not used
11
LIN Failure
12
Vbat Range 1 (UV)3) [only âSBC Active Modeâ]
13
Vbat Range 2 (OV) [only âSBC Active Modeâ]
Output Data after Wake-up2)
VCC Temperature Prewarning
HS-LED fail (OC / OT)
VINT-Fail (âactive lowâ)
LS1/2 (OC / OT)
Window Watchdog Reset
Wake-Up via MON1
Wake-Up via MON2
Wake-Up via MON3
Wake-Up via MON4
Wake-Up via MON5
âreservedâ / not used
Bus Wake-Up via LIN Msg.
End of Cyclic Wake Period
âlowâ4)
Data Sheet
23
Rev. 3.01, 2008-04-15
|
▷ |