TLE4998S3C Datasheet, PDF (21/36 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4998S3C
Signal Processing
6.5
Clamping
The clamping function is useful for separating the output range into an operating range
and error ranges. If the magnetic field is exceeding the selected measurement range, the
output value OUT is limited to the clamping values. Any value in the error range is
interpreted as an error by the sensor counterpart.
Table 12 Clamping
Parameter
Symbol Limit Values Unit
min. max.
Register size
CL,CH
2x7
bit
Clamping value low OUTCL 0
65024
Clamping value high OUTCH 511 65535
Clamping quantization ∆OUTCx
512
steps
LSB16
LSB16
LSB16
1) For CL = 0 and CH = 127, the clamping function is disabled
2) OUTCL < OUTCH mandatory
3) Quantization starts for CL at 0 LSB16 and for CH at 65535 LSB16
Notes
(0...127)
1)
1) 2)
3)
The clamping values are calculated by:
Clamping value low (deactivated if CL=0):
OUTCL = CL ⋅ 32 ⋅ 16
Clamping value high (deactivated if CH=127):
OUTCH = (CH + 1) ⋅ 32 ⋅ 16 – 1
Data Sheet
21
Rev 1.1, 2009-09