English
Language : 

TLE4998S3C Datasheet, PDF (11/36 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4998S3C
Operating Range
4
Operating Range
The following operating conditions must not be exceeded in order to ensure correct
operation of the TLE4998S3C. All parameters specified in the following sections refer to
these operating conditions, unless otherwise indicated.
Table 3
Operating Range
Parameter
Symbol Limit Values
min. max.
Supply voltage
VDD
Output pull-up voltage3)
Load resistance3)
Output current3)
Junction temperature
Vpull-up
RL
IOUT
TJ
4.5
4.11)
-
1
0
- 40
5.5
162)
18
-
5
125
1504)
Unit
V
V
V
kΩ
mA
°C
Notes
Extended range
For 5000 h
For 1000 h not additive
1) For reduced output accuracy
2) For supply voltages > 12 V, a series resistance Rseries ≥ 100 Ω is recommended
3) Output protocol characteristics depend on these parameters, RL must be according to max. output current
4) For reduced magnetic accuracy; extended limits are taken for characteristics
Keeping signal levels within the limits specified in this table ensures operation without
overload conditions.
Data Sheet
11
Rev 1.1, 2009-09