Reset and Initialization
Accessing Subfunctions after Hardware Reset
The functions LBI EBC, LBI DMSM, SSC, and IOM®-2 must be made accessible by
additional programming before they can be used.
Note that LBI functions are only available, if the DEMUX pin is set to â0â (PCI Interface
Mode).
The Table 22 shows the programming required to access the MUNICH32X
subfunctions.
Table 22 Programming after Hardware Reset
Subfunction Required Register Programming
LBI EBC/
Mailbox
⢠bit LCONF.EBCRES must be set to â1â
LBI DMSM ⢠bit CONF.LBI must be set to â1â
⢠bit LCONF.LBIRES must be set to â1â