TLE9262-3QX
General Product Characteristics
Table 4 Current Consumption (cont’d)
Current consumption values are specified at Tj = 25°C, VS = 13.5V, all outputs open (unless otherwise specified)
Parameter
Symbol
Values
Unit Note / Test Condition Number
Min.
Current consumption for
ISleep,VCC3,25 –
VCC3 in SBC Sleep Mode in
stand-alone configuration
Current consumption for
ISleep,VCC3,85 –
VCC3 in SBC Sleep Mode in
stand-alone configuration
Current consumption for HSx IStop,HSx,25 –
in SBC Stop Mode
Current consumption for HSx IStop,HSx,85 –
in SBC Stop Mode
Current consumption for
cyclic sense function
Current consumption for
cyclic sense function
IStop,CS25
–
IStop,CS85
–
Current consumption for
watchdog active in Stop
Mode
IStop,WD25
–
Current consumption for
watchdog active in Stop
Mode
IStop,WD85
–
Current consumption for
IStop,FOx
–
active fail outputs (FO1..3)
Typ.
40
50
525
575
20
24
20
24
1.0
Max.
60
µA
70
µA
650 µA
700 µA
26
µA
35
µA
26
µA
35
µA
2.0 mA
1)5)SBC Sleep Mode;
VCC3 = ON (no load,
stand-along config.);
LIN, CAN,
WK1..3 = OFF
1)3)5)SBC Sleep Mode;
Tj = 85°C; VCC3 = ON
(no load, stand-along
config.); LIN, CAN,
WK1..3 = OFF
5)8)SBC Stop Mode;
Cyclic Sense & HSx=
ON (no load);
LIN, CAN,
WK1..3 = OFF
3)5)8)SBC Stop Mode;
Tj = 85°C;
Cyclic Sense & HSx =
ON (no load);
LIN, CAN,
WK1..3 = OFF
5)9)10)SBC Stop Mode;
WD = OFF
3)5)9)10)SBC Stop
Mode;
Tj = 85°C;
WD = OFF
3)SBC Stop Mode;
Watchdog running
P_4.4.21
P_4.4.22
P_4.4.33
P_4.4.34
P_4.4.23
P_4.4.27
P_4.4.30
3)SBC Stop Mode;
Tj = 85°C;
Watchdog running
3)all SBC Modes;
Tj = 25°C; FOx = ON
(no load);
P_4.4.31
P_4.4.24
1) If the load current on VCC1 will exceed the configured VCC1 active peak threshold IVCC1,Ipeak1,r or IVCC1,Ipeak2,r,
the current consumption will increase by typ. 2.9mA to ensure optimum dynamic load behavior. Same applies to VCC2. For
VCC3 the current consumption will increase by typ. 1.4mA. See also Chapter 6, Chapter 7, Chapter 8.
2) CAN not configured in selective wake mode.
3) Not subject to production test, specified by design.
4) Current consumption adder also applies for during WUF detection (frame detect mode) when CAN Partial Networking is
activated.
5) Current consumption adders of features defined for SBC Sleep Mode also apply for SBC Stop Mode and vice versa (unless
otherwise specified).
Data Sheet
20
Rev. 1.1, 2014-09-26