English
Language : 

TLE42694_14 Datasheet, PDF (19/33 Pages) Infineon Technologies AG – Low Dropout Fixed Voltage Regulator
TLE42694
Block Description and Electrical Characteristics
Reset Adjust Function
The undervoltage reset switching threshold can be adjusted according to the application’s needs by connecting
an external voltage divider (RADJ1, RADJ2) at pin RADJ. For selecting the default threshold connect pin RADJ to GND.
When dimensioning the voltage divider, take into consideration that there will be an additional current constantly
flowing through the resistors.
With a voltage divider connected, the reset switching threshold VRT,new is calculated as follows:
(3)
VRT, new
=
R-----A---D----J--,--1----+-----R----A----D----J--,--2-
RADJ, 2
×
VR A D J,
th
with
• VRT,new: the desired new reset switching threshold
• RADJ1, RADJ2: resistors of the external voltage divider
• VRADJ,th: reset adjust switching threshold given in Table 9 “Electrical Characteristics Reset Function” on
Page 20
Supply I
Co n tr o l
In t.
Supply
VRADJ,th
OR
GND
BlockDiagram_ResetAdjust.vsd
Figure 6 Block Diagram Reset Function
ID,ch
ID,dch
VDST
Q
RRO
RO
CQ
I RO
VDD
RRO,ext
Re se t
RADJ,1
M ic ro-
Cont rolle r
D
CD
RADJ
I RADJ
RADJ,2
GND
Data Sheet
19