Functional Description
2.2.6
Short Term Bus Under voltage
Short-term PFC bus under voltage (Figure 12) is detected if the duration of the under voltage does not exceed
800 ms (timer remains below t < 800 ms). In this case, the PFC and inverter drivers are immediately switched
off and the controller continuously monitors the status of the bus voltage in a latched power-down mode (ICC <
170 µA). If the signal at the OVP PIN exceeds 18 µA and the rated bus voltage is above 12.5 % while the timer
is below t < 800 ms, the controller restarts from power-up. The timer resets to 0 when entering the run mode.
Figure 12 Bus Under voltage – Short
Datasheet
18
Rev. 1.3, 2016-01-15