English
Language : 

TLE6251-3G Datasheet, PDF (16/36 Pages) Infineon Technologies AG – High Speed CAN-Transceiver with Wake and Failure Detection
TLE6251-3G
Wake-Up Functions
6.3
Mode Change via the EN and NSTB pin
Besides a mode change issued by a Wake-Up event, the operation mode on the TLE6251-3G can be changed by
changing the signals on the EN and NSTB pins. Therefore the power supplies VCC and VIO have to be active.
According to the mode diagram in Figure 4 the operation mode can be changed directly from Sleep mode to the
Receive-Only mode, Normal Operation mode. A change from Sleep mode direct to Stand-By mode is only possible
via a Wake-Up event. For example by setting the NSTB pin and the EN pin to logical “High” the TLE6251-3G
changes from Sleep mode to Normal Operation mode (see Figure 8).
The pins EN and NSTB have a hysteresis between the logical “Low” and the logical “High” signal in order to avoid
any toggling during the operation mode change.
NSTB
VM,H
EN
VM,H
thSLP
VM,L
t
VM,L
INH
tMode
tMode
t
Sleep mode
Normal Operation
mode
Figure 8 Wake-Up via Mode Change
Go-To-Sleep
command
t
Sleep mode
Data Sheet
16
Rev. 1.1, 2011-06-06