Electrical Characteristics (continued)
Parameter and Conditions
at Tj = –40 … +150 °C, unless otherwise specified
and supply voltage range VS = 8 ... 20V; fPWM = 20kHz;
VCBxx>7.5V
Diagnosis and Protection Functions
Undervoltage warning at ERR
@ TJ = -40°C
@ TJ = +25°C
@ TJ = +150°C
Undervoltage shut down of output stage
@ TJ = -40°C
@ TJ = +25°C
@ TJ = +150°C
Over-temperature warning11
Hysteresis for over-temperature warning
Short circuit protection shut down time delay
Short circuit criteria (VDS of Mosfets) @
VMFP=3V12
@ TJ = -40°C
@ TJ = +25°C
@ TJ = +150°C
Factor between VMFP and max. VGXX
@ 2V < VMFP < 4V
Disable input level
Enable input level 13
Disable input hysteresis
Error level @ 1.6mA IERR
Shoot through option
Shoot through protection activated
Shoot through option activated
Datasheet TLE6280GP
Symbol
Values
Unit
min typ max
VBxx-VSxx
VBxx-VSxx
TJ(OV)
∆TJ(OV)
tSCP(off)
VDS(SCP)
V
8 9.4 10
8 9.3 10
8 9.0 10
V
5.5 7.2 7.5
5.0 6.6 7.2
4.0 5.6 7.2
150 170 190 °C
20
°C
7 11 15 µs
V
VGxxMax/VMFP
1.4 1.85
--
-- 1.90
--
-- 1.95 2.3
1.8
2 2.27
VMFP(DIS)
VMFP(EN)
∆VMFP(DIS)
VERR
--
--
2.5
--
-- 500
--
--
1.1 V
-- V
-- mV
1.0 V
VMFP
VMFP
4V
4.5
--
-- V
11 specified by design – not subject to production test
12 Periodic short circuit condition will be detected within several cycles, if the duty cycle is more than 10%
13 If the device is enabled, the slope of dU(VMFP)/dt has to be higher than 3.5V/50µs
14
2007-07-19