English
Language : 

TLE4997 Datasheet, PDF (14/36 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor for Industrial Use
TLE4997I
Electrical and Magnetic Parameters
5
Electrical and Magnetic Parameters
Table 4
Electrical Characteristics
Parameter
Symbol Limit Values
Unit Notes
min. typ. max.
Output voltage range
VOUT 5
- 95 % VDD
Supply current
IDD
3 7.5 10 mA Also in extended VDD
range1), IOUT= 0mA
Output current @ OUT IOUTsh -30 - 30 mA For operating supply
shorted to supply lines
voltage range only
Zero field voltage
Zero field voltage drift
Ratiometry error
VZERO -100
∆VZERO -0.5 -
-0.5 -
ERAT -0.25 -
100 %
Of VDD 2)
0.5 % VDD In lifetime 3)
0.5 % VDD Over temperature3)
+0.25 %
Of VDD4)5)
Thermal resistance
RthJA -
- 219 K/W Junction to air
RthJC -
- 47 K/W Junction to case
Power on time
tPon
-
-1
ms
∆ VOUT ≤ ± 5% of VDD
10
∆ VOUT ≤ ± 1% of VDD
Power On Reset level VDDpon 2
-4
V
Output DAC quantization ∆VOUT
1.22
mV @ VDD = 5 V
Output DAC resolution -
12
bit
Output DAC bandwidth fDAC
- 3.2 -
kHz Interpolation filter 6)
Output noise
Vnoise -
- 4.68 mVpp 5% exceeded 7)8)
Differential non-linearity DNL -1 - 1
LSB Of output DAC
Signal delay
tDS
-
- 250 µs
@ 100 Hz 9)
1) For VOUT within the range of 5%... 95% of VDD
2) Programmable in steps of 1.22 mV ( @ VDD = 5V ).
3) For small sensitivity settings. For higher sensitivities, the magnetic offset drift is dominant.
This means that, for an example with a calibrated 60mV/mT sensitivity, the typical output drift
might be given due to the allowed magnetic offset tolerance up to ±0.5 mT x 60 mV/mT = ±30 mV @5 V VDD.
4) For 4.5 V≤VDD≤5.5 V and within nominal VOUT range; see “Ratiometry” on Page 15 for details on ERAT.
5) For the maximum error in the extended voltage range, see “Ratiometry” on Page 15.
6) More information, see “DAC Input Interpolation Filter” on Page 22.
7) 100 mT range, sensitivity 60 mV/mT, LP-filter 244 Hz, 160 Hz external RC low pass filter as application circuit.
8) ’5% exceeded’ means that 5 of 100 continuously measured VOUT samples are out of limit.
9) A sinusoidal magnetic field is applied, VOUT shows amplitude of 20% of VDD, no LP filter is selected.
Data Sheet
14
V 1.0, 2007-06