English
Language : 

TLE7250V_15 Datasheet, PDF (11/34 Pages) Infineon Technologies AG – High Speed CAN-Transceiver
TLE7250VLE
TLE7250VSJ
Functional Description
4.3
Power-up and Undervoltage Condition
By detecting an undervoltage event, either on the transmitter supply VCC or the digital supply VIO, the transceiver
TLE7250V changes the mode of operation. Turning off the digital power supply VIO, the transceiver powers down
and remains in the power-down state. While switching off the transmitter supply VCC, the transceiver either
changes to the forced power-save mode, or remains in power-save mode (details see Figure 5).
VIO “on”
VCC “on”
NEN “0”
normal-operating
mode
NEN VCC VIO
0 “on” “on”
power-down
state
NEN VCC VIO
“X” “X” “off”
VIO “on”
VCC “off”
NEN “0”
VIO “on”
VCC “on”
NEN “0”
VIO “on”
VCC “X”
NEN “1”
VIO “on”
VCC “X”
NEN “1”
power-save
mode
NEN VCC VIO
1 “X” “on”
VIO “on”
VCC “off”
NEN “0”
VIO “on”
VCC “on”
NEN “0”
forced power-save
mode
NEN VCC VIO
0 “off” “on”
VIO “on”
VCC “X”
NEN “1”
Figure 5 Power-up and undervoltage
Table 2 Modes of operation
Mode
NEN
VIO
VCC
Normal-operating “low” “on”
“on”
Power-save
“high” “on”
“X”
Forced power-save “low” “on” “off”
Power-down state “X”
“off”
“X”
Bus Bias Transmitter
VCC/2
“on”
floating “off”
floating “off”
floating
“off”
Normal-mode Low-power
Receiver
Receiver
“on”
not available
“off”
not available
“off”
not available
“off”
not available
Data Sheet
11