English
Language : 

ICS831721I Datasheet, PDF (7/17 Pages) Integrated Device Technology – Differential Clock/Data Multiplexer
ICS831721I Data Sheet
Parameter Measurement Information
3.3V±0.3V
VDD
33Ω
HCSL
33Ω
IREF
GND
475Ω
0V
50Ω
49.9Ω
50Ω
49.9Ω
Qx
2pF
nQx
2pF
3.3V HCSL Output Load AC Test Circuit
VDD
nCLK[0:1]
V
PP
CLK[0:1]
GND
Cross Points
V
CMR
Differential Input Level
DIFFERENTIAL CLOCK/DATA MULTIPLEXER
3.3V±0.3V
SCOPE
VDD
50Ω
HCSL
50Ω
IREF
GND
475Ω
0V
This load condition is used for IDD, tsk(pp), tsk(i), tPD and tjit
measurements.
3.3V HCSL Output Load AC Test Circuit
Spectrum of Output Signal Q
A0
MUX selects active
input clock signal
MUX_ISOL = A0 – A1
A1
MUX selects static input
MUX_ISOLATION
ƒ
(fundamental)
Frequency
nCLK[0:1]
CLK[0:1]
nQ
Q
tPD
Propagation Delay
ICS831721AGI REVISION A AUGUST 19, 2011
Part 1
nQx
Qx
nQy Par t 2
Qx
t sk(pp)
Part-to-Part Skew
7
©2011 Integrated Device Technology, Inc.