English
Language : 

ICS87001I-01 Datasheet, PDF (5/14 Pages) Integrated Device Technology – Maximum output frequency
ICS87001I-01 Data Sheet
LVCMOS/LVTTL CLOCK DIVIDER
AC Electrical Characteristics
Table 5A. AC Characteristics, VDD = VDDO = 3.3V ± 5%, TA = -40°C to 85°C
Symbol
Parameter
Test Conditions
Minimum
fOUT
tPD
Output Frequency
Propagation Delay,
Low to High; NOTE 1
N2
3.6
N>2
4.3
tsk(pp)
Part-to-Part Skew; NOTE 2, 3
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
0.4
40
tEN
Output Enable Time
tDIS
Output Disable Time
Typical
4.6
5.5
0.6
Maximum
250
5.7
6.7
750
1.0
60
10
10
Units
MHz
ns
ns
ps
ns
%
ns
ns
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the device is
mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after thermal equilibrium
has been reached under these conditions.
All parameters measured at fIN  250MHz unless noted otherwise.
NOTE 1: Measured from the VDD/2 of the input to VDDO/2 of the output.
NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage, same frequency, same temperature and
with equal load conditions. Using the same type of input on each device, the output is measured at VDDO/2.
NOTE 3: This parameter is defined in accordance with JEDEC Standard 65.
Table 5B. AC Characteristics, VDD = 3.3V ± 5%, VDDO = 2.5V ± 5%, TA = -40°C to 85°C
Symbol
Parameter
Test Conditions
Minimum
fOUT
tPD
Output Frequency
Propagation Delay,
Low to High; NOTE 1
N2
3.5
N>2
4.5
tsk(pp)
Part-to-Part Skew; NOTE 2, 3
tR / tF
odc
Output Rise/Fall Time
Output Duty Cycle
20% to 80%
0.4
40
tEN
Output Enable Time
tDIS
Output Disable Time
Typical
4.8
5.7
0.7
Maximum
250
6.2
6.9
590
1.1
60
10
10
Units
MHz
ns
ns
ps
ns
%
ns
ns
NOTE: Electrical parameters are guaranteed over the specified ambient operating temperature range, which is established when the device is
mounted in a test socket with maintained transverse airflow greater than 500 lfpm. The device will meet specifications after thermal equilibrium
has been reached under these conditions.
All parameters measured at fIN  250MHz unless noted otherwise.
NOTE 1: Measured from the VDD/2 of the input to VDDO/2 of the output.
NOTE 2: Defined as skew between outputs on different devices operating at the same supply voltage, same frequency, same temperature and
with equal load conditions. Using the same type of input on each device, the output is measured at VDDO/2.
NOTE 3: This parameter is defined in accordance with JEDEC Standard 65.
ICS87001BGI-01 REVISION A JANUARY 23, 2013