English
Language : 

ICS950208 Datasheet, PDF (15/19 Pages) Integrated Circuit Systems – Programmable Timing Control Hub for P4
Integrated
Circuit
Systems, Inc.
ICS950208
Electrical Characteristics - 3V66
TA = 0 - 70°C; VDD=3.3V +/-5%; CL = 10-30 pF (unless otherwise specified)
PARAMETER SYMBOL
CONDITIONS
Output Frequency
Output Impedance
FO1 1
RDSP11
VO = VDD*(0.5)
Output High Voltage VOH1
IOH = -1mA
Output Low Voltage VOL1
IOL = -1mA
Output High Current IOH1
VOH =1.0V
VOH =3.135V
Output Low Current IOL1
VOL = 1.95 V
VOL = 0.4V
Rise Time
tr1
VOL = 0.4V, VOH =2.4V
Fall Time
tf1
VOH = 2.4V, VOL = 0.4V
Duty Cycle
dt1
VT = 1.5V
Skew
tf1
VT = 1.5V
Jitter
tjcyc-cyc1
VT = 1.5V
1 Guaranteed by design,not 100% tested in production
Electrical Characteristics - 24, 48MHz
TA = 0 - 70°C; VDD = 3.3V +/-5%; CL= 10-30pF (unlessotherwise stated)
PARAMETER
SYMBOL
CONDITIONS
Output Frequency
Output Impedance
FO1
RDSN1 1
VO = VDD*(0.5)
VO = VDD*(0.5)
Output High Voltage
VOH1
IOH = -1mA
Output Low Voltage
VOL1
IOL = -1mA
Output High Current
IOH1
VOH =1.0V
VOH =3.135V
Output Low Current
IOL1
VOL = 1.95 V
VOL = 0.4V
Rise Time
tr1 1
VOL = 0.4V, VOH =2.4V
Fall Time
tf1 1
VOH = 2.4V, VOL = 0.4V
Duty Cycle
dt11
VT = 1.5V
Jitter
tjcyc-cyc 1
VT = 1.5V
1 Guaranteed by design,not 100% tested in production
MIN TYP MAX UNITS
66.66
MHz
12
55 Ω
2.4
V
0.55 V
-33 mA
-33
30
mA
38
0.5 1.94 2 ns
0.5 1.78 2 ns
45 50.7 55 %
82 500 ps
45 245 250 ps
MIN TYP MAX
24, 48
12
55
2.4
0.55
-29
-23
29
27
1 1.25 2
1 1.25 2
45 52 55
150 350
UNITS
MHz
Ω
V
V
mA
mA
ns
ns
%
ps
0464B—08/04/03