English
Language : 

ICS1887 Datasheet, PDF (13/14 Pages) Integrated Circuit Systems – FDDI / Fast Ethernet PHYceiverTM
Clock Recovery
ICS1887
T#
PARAMETER (conditions)
t1 Ideal data recovery window
t2 Actual data recovery window
t3 Data recovery window truncation
t4 CD assert to data acquired
MIN
TYP
MAX UNITS
—
—
8
ns
6
—
8
ns
0
—
1
ns
—
—
5
µs
13