IS61S6432 Datasheet, PDF (6/20 Pages) Integrated Circuit Solution Inc – 64K x 32 SYNCHRONOUS PIPELINE STATIC RAM
IS61S6432
DC ELECTRICAL CHARACTERISTICS(1,2) (Over Operating Range)
Symbol Parameter
Test Conditions
Min.
Max.
Unit
VOH
Output HIGH Voltage
IOH = –5.0 mA
2.4
—
V
VOL
Output LOW Voltage
IOL = 5.0 mA
—
0.4
V
VIH
Input HIGH Voltage
2.0 VCCQ + 0.3 V
VIL
Input LOW Voltage
–0.3
0.8
V
ILI
Input Leakage Current
GND ≤ VIN ≤ VCCQ(2)
Com. –5
5
µA
Ind. –10
10
ILO
Output Leakage Current
GND ≤ VOUT ≤ VCCQ, OE = VIH
Com. –5
5
µA
Ind. –10
10
Notes:
1. MODE pin have an internal pull-up. ZZ pin has an internal pull-down. These pins may be a No Connect,
tied to GND,or tied to VCCQ.
2. MODE pin should be tied to Vcc or GND. They exhibit ±30 µA maximum leakage current when tied
to ≤ GND + 0.2V or ≥ Vcc – 0.2V.
POWER SUPPLY CHARACTERISTICS (Operating Range)
Symbol Parameter
Test Conditions
-200(1)
-166
-133
-117
Min. Max. Min. Max. Min. Max. Min. Max. Unit
ICC AC Operating Device Selected,
Com. — 400
Supply Current All Inputs = VIL or VIH
Ind. — —
OE = VIH, Cycle Time ≥ tKC min.
ISB
Standby Current Device Deselected,
Com. — 100
VCC = Max.,
CLK Cycle Time ≥ tKC min.
Ind. — —
IZZ
Power-Down ZZ = VCCQ, CLK Running
Mode Current All Inputs ≤ GND + 0.2V
or ≥ VCC – 0.2V
Note:
1. ADVANCE INFORMATION ONLY.
Com. — 5
Ind. — —
— 215
——
— 70
——
—5
——
— 205
——
— 60
——
—5
——
— 195 mA
— 205
— 50 mA
— 60
— 5 mA
— 10
Symbol Parameter
Test Conditions
-5
Min. Max.
ICC
AC Operating Device Selected,
Com. — 175
Supply Current All Inputs = VIL or VIH
Ind. — 185
OE = VIH, Cycle Time ≥ tKC min.
ISB
Standby Current Device Deselected,
Com. — 25
VCC = Max.,
CLK Cycle Time ≥ tKC min.
Ind. — 35
IZZ
Power-Down ZZ = VCCQ, CLK Running Com. — 5
Mode Current All Inputs ≤ GND + 0.2V
Ind. — 10
or ≥ VCC – 0.2V
-6
Min. Max.
— 165
— 175
— 25
— 35
—5
— 10
-7
Min. Max.
— 150
— 160
— 25
— 35
—5
— 10
-8
Min. Max. Unit
— 140 mA
— 150
— 25 mA
— 35
— 5 mA
— 10
6
Integrated Circuit Solution Inc.
SSE003-0B