Rev B1, Page 6/23
ELECTRICAL CHARACTERISTICS
Operating conditions:
VPA, VPD = 5 V ±10 %, Tj = -40...125 °C, IBM adjusted to 200 µA , 4 mm NdFeB magnet, unless otherwise noted
Item Symbol Parameter
No.
Conditions
Unit
Min. Typ. Max.
Line Driver Outputs
P01 Vs()hi
Saturation Voltage hi
Vs() = VPD − V();
CfgDR(1:0) = 00, I() = -4 mA
CfgDR(1:0) = 01, I() = -50 mA
CfgDR(1:0) = 10, I() = -50 mA
CfgDR(1:0) = 11, I() = -20 mA
200 mV
700 mV
700 mV
400 mV
P02 Vs()lo
Saturation Voltage lo
CfgDR(1:0) = 00, I() = -4 mA
CfgDR(1:0) = 01, I() = -50 mA
CfgDR(1:0) = 10, I() = -50 mA
CfgDR(1:0) = 11, I() = -20 mA
200 mV
700 mV
700 mV
400 mV
P03 Isc()hi
Short-Circuit Current hi
V() = 0 V;
CfgDR(1:0) = 00
CfgDR(1:0) = 01
CfgDR(1:0) = 10
CfgDR(1:0) = 11
-12
-120
-120
-60
-4
mA
-50 mA
-50 mA
-20 mA
P04 Isc()lo
Short-Circuit Current lo
V() = VPD;
CfgDR(1:0) = 00
CfgDR(1:0) = 01
CfgDR(1:0) = 10
CfgDR(1:0) = 11
4
12
mA
50
120 mA
50
120 mA
20
60
mA
P05 Ilk()tri
Leakage Current Tristate
TRIHL(1:0) = 11
-100
100 µA
P06 tr()
Rise-Time lo to hi at Q
P07 tf()
Fall-Time hi to lo at Q
RL = 100 Ω to VND;
CfgDR(1:0) = 00
CfgDR(1:0) = 01
CfgDR(1:0) = 10
CfgDR(1:0) = 11
RL = 100 Ω to VND;
CfgDR(1:0) = 00
CfgDR(1:0) = 01
CfgDR(1:0) = 10
CfgDR(1:0) = 11
5
20
ns
5
20
ns
50
350
ns
5
40
ns
5
20
ns
5
20
ns
50
350
ns
5
40
ns
OPERATING REQUIREMENTS: Serial Interface
Operating conditions: VPA, VPD = 5 V ±10 %, Ta = -40...125 °C, IBM calibrated to 200 µA;
Logic levels referenced to VND: lo = 0...0.45 V, hi = 2.4 V...VPD
Item Symbol Parameter
No.
Conditions
SSI Protocol (ENSSI = 1)
I001
I002
I003
TMAS
tMASh
tMASl
Permissible Clock Period
Clock Signal Hi Level Duration
Clock Signal Lo Level Duration
tout determined by CFGTOS
Min.
Unit
Max.
250
2x tout
ns
25
tout
ns
25
tout
ns
Figure 1: I/O Interface timing with SSI protocol