English
Language : 

IC-MQF_15 Datasheet, PDF (19/38 Pages) IC-Haus GmbH – Sin/Cos INTERPOLATION IC WITH RS422 DRIVER
iC-MQF PROGRAMMABLE 12-BIT preliminary
Sin/Cos INTERPOLATION IC WITH RS422 DRIVER
Rev C1, Page 19/38
Calibration 1, 2, 3, Test 5
These modes are used to condition the input signals
and calibrate iC-MQF. In mode Calibration 1 the user
can measure the IBN bias current and the zero channel
analog signals are available (PCH0 and NCH0) (for
zero channel calibration see page 25).
In mode Test 5 the conditioned sine and cosine signals
are output (PSIN, NSIN, PCOS and NCOS). In mode
Calibration 2 the conditioned sine and cosine signals
are output with a gain which is reduced by factor 6
(PCH1, NCH1, PCH2 and NCH2). The intermediate
potentials VDC1 and VDC2 are provided on Pin PZ and
Pin NZ if VOS12 is set to 0x3. (For a description of the
calibration process, see page 23).
In mode Calibration 3 the internal temperature mon-
itoring signals are provided. Calibration of the bias
current source and temperature monitoring is described
on page 17.
TEST 6
The input voltages at the pins X3 to X6 can be checked
in mode Test 6. The following settings are required
here:
• MUX = 0x40
System Test and Digital Calibration
This mode enables the signal conditioning to be ad-
justed using comparated sine and cosine signals. At a
resolution of 8 the interpolator generates a switchpoint
every 45 degrees. The objective of the calibration pro-
cedure is a pulse duty cycle of exactly 50% respectively
for A4, B4 und A8, B8.
System Test
Pin Signal
Description
PA A4
NA A8
Offset CH1
Phase deviation from 90° between
CH1 and CH2
PB B4
Offset CH2
NB B8
Amplitude deviation between
CH1 and CH2
PZ ZIn
NZ TP1
Digital zero signal, unmasked
Verification of line count (pulses) between two
zero pulses
Low signal: verification running (state after
power on reset)
High signal: verification finished
An error messaging at ERR is valid after the
second zero signal (enable required).
The following settings are required for mode System Test:
MODE = 0x0B, SELRES = 0x0002, SELHYS = 0xF,
CFGABZ(7:4) = ’0000’
Table 15: Digital Calibration Signals