English
Language : 

IC-JX Datasheet, PDF (16/36 Pages) IC-Haus GmbH – 16-FOLD 24 V HIGH-SIDE DRIVER WITH μC INTERFACE
iC-JX
16-FOLD 24 V HIGH-SIDE DRIVER WITH µC INTERFACE
Interrupt Status Register A (read only)
Bit
7
6
5
4
3
Name
DCHI
IET2
IET1
ISCI
-
Rev C1, Page 16/36
Adr. 0x04
reset entry: 0x00
2
1
0
ET2
ET1
SCS
Change-of-input data, overtemperatur, overcurrent (interrupts stored)
Bit7
0
No message
(r)
DCHI
1
Interrupt through change-of input message
Bit6
0
No message
(r)
IET2
1
Interrupt through excessive temperature level 2
Bit5
0
No message
(r)
IET1
1
Interrupt through excessive temperature level 1
Bit4
0
No message
(r)
ISCI
1
Interrupt through overcurrent message
Excessive temperature status, overcurrent status (real time signals, at the time of readout)
Bit2
0
No error message
(r)
ET2
1
Excessive temperature level 2 (shutdown)
Bit1
0
No error message
(r)
ET1
1
Excessive temperature level 1 (warning)
Bit0
0
No error message
(r)
SCS
1
Overcurrent status (e.g. caused by low-side short circuit)
Interrupt Status Register B (read only)
Bit
7
6
Name
IEOC
ISD
5
4
3
IUSD
IUSA
-
2
EOC
1
USD
Adr. 0x05
reset entry: 0x00
0
USA
A/D-Converter, Bursts, Undervoltage (interrupts stored)
Bit7
0
No message
(r)
IEOC
1
Interrupt by the A/D-Converter
Bit6
0
No message
(r)
ISD
1
Interrupt caused by bursts at VDD
Bit5
0
No message
(r)
IUSD
1
Interrupt caused by undervoltage at VDD
Bit4
0
No message
(r)
IUSA
1
Interrupt caused by undervoltage at VCC
A/D-Converter, Undervoltage (real time signals, at the time of readout)
Bit2
0
No message
(r)
EOC
1
A/D conversion completed (End of Conversion)
Bit1
0
No message
(r)
USD
1
Undervoltage at VDD
Bit0
0
No message
(r)
USA
1
Undervoltage at VCC
Read access gates off changes to the register; the register is reenabled only when reset via EOI. Any successive
interrupts which occur at DCHI, IET2, IET1, ISCI, IEOC, ISD, IUSD und IUSA during the read-out phase and
before a reset with EOI are trapped by an interrupt pipeline. If this happens, the message at NINT resp. D1/SOC
or D2/SOB cannot be deletet by EOI, i.e. NINT resp. D1/SOC or D2/SOB constantly remains on low. In this
instance, EOI fills the overcurrent message from the pipeline.