English
Language : 

HCPL-7723 Datasheet, PDF (6/12 Pages) Agilent(Hewlett-Packard) – 50 MBd 2 ns PWD High Speed CMOS Optocoupler
All Agilent data sheets report the
creepage and clearance inherent
to the optocoupler component
itself. These dimensions are
needed as a starting point for the
equipment designer when
determining the circuit insulation
requirements. However, once
mounted on a printed circuit
board, minimum creepage and
clearance requirements must be
met as specified for individual
equipment standards. For
creepage, the shortest distance
path along the surface of a
printed circuit board between the
solder fillets of the input and
output leads must be considered.
There are recommended
techniques such as grooves and
ribs, which may be used on a
printed circuit board to achieve
desired creepage and clearances.
Creepage and clearance distances
will also change depending on
factors such as pollution degree
and insulation level.
VDE 0884 Insulation Related Characteristics (Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values (maximum values allowed in the
event of a failure, also see Thermal Derating curve,
Figure 11)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
HCPL-7723
Option 060
VIORM
VPR
I-IV
I-IV
I-III
55/85/21
2
630
1181
VPR
945
VIOTM
6000
TS
175
IS,INPUT 230
PS,OUTPUT 600
RIO
≥ 109
HCPL-0723
Option 060 Units
I-IV
I-III
55/85/21
2
560
1050
V peak
V peak
840
V peak
4000
V peak
150
°C
150
mA
600
mW
≥ 109
Ω
*Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
(VDE 0884), for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.