5
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I - IV
I - III
I-II
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
891
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875=VPR, 100% Production Test with
tm=1 sec, Partial discharge < 5 pC
VPR
1670
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec,
VPR
Partial discharge < 5 pC
1336
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 10 sec)
VIOTM
6000
Vpeak
Safety-limiting values - maximum values allowed in the
event of a failure.
Case Temperature
Input Current**
Output Power**
TS
175
°C
IS,INPUT
400
mA
PS, OUTPUT
1200
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations
section, IEC/EN/DIN EN 60747-5-2 for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – °C