Regulatory Information
The HCPL-7100/1 has been
approved by the following
organizations:
UL
Recognized under UL 1577,
Component Recognition Program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
VDE
Approved according to VDE
0884/06.92
Insulation and Safety Related Specifications
Parameter
Symbol Value Units
Conditions
Min. External Air Gap
(External Clearance)
L(IO1) 7.4 mm Measured from input terminals to output terminals,
shortest distance through air
Min. External Tracking L(IO2) 8.0 mm Measured from input terminals to output terminals,
Path (External Creepage)
shortest distance path along body
Min. Internal Plastic
Gap (Internal Clearance)
0.5 mm Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity
Tracking Resistance
(Comparative
Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 PART 1
Isolation Group
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
VDE 0884 (06.92) Insulation Characteristics
Description
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)*
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
VPR = 1.875 x VIORM, Production test with tp = 1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a**
VPR = 1.5 x VIORM, Type and sample test, tp = 60 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage**
(Transient Overvoltage, tTR = 10 sec)
Safety-limiting values (Maximum values allowed in the event
of a failure, also see Figure 15)
Case Temperature
Input Power
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol Characteristic
VIORM
I-IV
I-III
40/85/21
2
848
VPR
1591
VPR
1273
VTR
6000
TS
PS,INPUT
PS,OUTPUT
RS
175
80
250
≥ 1 x 1012
Unit
V peak
V peak
V peak
V peak
°C
mW
mW
Ω
*This part may also be used in Pollution Degree 3 environments where the rated mains voltage is ≤ 300 V rms (per DIN VDE 0110).
**Refer to the front of the optocoupler section in the current catalog for a more detailed description of VDE 0884 and other product
safety requirements.
Note: Optocouplers providing safe electrical separation per VDE 0884 do so only within the safety-limiting values to which they are
qualified. Protective cut-out switches must be used to ensure that the safety limits are not exceeded.
1-405