English
Language : 

AMMC-3040 Datasheet, PDF (1/6 Pages) Agilent(Hewlett-Packard) – 18-36 GHz Double-Balanced Mixer with Integrated LO Amplifier/Multiplier
Agilent AMMC-3040
18-36 GHz Double-Balanced Mixer
with Integrated LO Amplifier/
Multiplier
Data Sheet
Features
• High IIP3 : +23 dBm
• Wide Bandwidth
• RF: 18-36 GHz
• LO: 18-36 GHz
• IF: DC-3 GHz
Chip Size:
Chip Size Tolerance:
Chip Thickness:
Pad Dimensions:
2520 x 760 µm (99.2 x 29.9 mils)
± 10 µm (± 0.4 mils)
100 ± 10 µm (4 ± 0.4 mils)
75 x 75 µm (3 ± 0.4 mils)
• Fundamental or Sub-Harmonic
Mixing
• Up or Down Converter
• Conversion Loss: 9.5dB
• P1dB : +17 dBm
Description
• Low LO Drive Power: + 2 dBm
• Usable to 42 GHz
The AMMC- 3040 is a broadband
Double- Balanced Mixer (DBM)
with an integrated high- gain LO
amplifier. This MMIC can be
used as either an up converter
or down converter in microwave
or millimeter wave applications.
If desired, the LO amplifier can
be biased to function as a
frequency multiplier to enable
second harmonic mixing of the
LO input. The mixer section
ofthe AMMC- 3040 is fabricated
using a suspended metal system
to create a unique, broadside-
coupled balun structure (patent
pending) to achieve exceptional
bandwidth. The MMIC provides
repeatable conversion loss
without tuning, making it highly
suitable for automated assembly
processes.
Applications
• Point-to-Point Radio
• LMDS
• SATCOM
AMMC-3040 Absolute Maximum Ratings[1]
Symbol Parameters/Conditions
Units Min. Max.
VD1, 2, 3, 4 Positive Drain Voltage
V
5
VG1, 2, 3, 4 Gate Voltage
V
-3.0 0.5
Idd
Total Drain Current
mA
550
Tch
Operating Channel Temp.
°C
+160
Tb
Operating Backside Temp.
°C
-55
Tstg
Storage Case Temp.
°C
-65 +165
Tmax
Maximum Assembly Temp (60 sec max) °C
+300
Note:
1. Operation in excess of any one of these conditions may result in permanent damage to this device.
Note: These devices are ESD sensitive. The following precautions are strongly recommended:
Ensure that an ESD approved carrier is used when dice are transported from one destination to another.
Personal grounding is to be worn at all times when handling these devices.