BOperation and Precautions
Operation
1.FPC insertion procedure. Connector installed on
the board.
1 1) Lift up the actuator. Use thumb or index finger.
Precautions
1 Do not apply excessive force or use any type of tool to operate the
actuator.
2 Fully insert the FPC in the connector parallel to mounting surface, with 2 The connector will assure reliable performance when the actuator is
the exposed conductive traces facing down.
open to 130Ëmaximum. Do not exceed this angle, as this may cause
permanent damage to the connector.
Over 130°
FPC conductor
surface
(Bottom side)
3 Rotate down the actuator until firmly closed. It is critical that the
inserted FPC is not moved and remains fully inserted.
3 Exercise caution when applying upward force to the connected FPC.
2.FPC removal
1 Lift up the actuator.
Carefully withdraw the FPC.