sProduct Specifications
Rating
Rated current 0.4 A DC
Rated voltage 40 V AC
Operating temperature range
-55ç to +85ç (Note 1)
Operating humidity range
Relative humidity 90% max. (No condensation)
Storage temperature range
-10ç to +50ç (Note 2)
Storage humidity range
Relative humidity 90% max.
Recommended FPC Thickness: = 0.2±0.03mm tin-lead plated (Note 3)
Item
Specification
Conditions
1. Insulation resistance 500 M ø min.
100 V DC
2. Withstanding voltage No flashover or insulation breakdown.
120 V AC /one minute
3. Contact resistance 100 m ohms max.
1 mA
* Including FPC conductor resistance
4. Durability
Contact resistance: 100 m ø max.
20 cycles
(insertion/ withdrawal) No damage, cracks, or parts dislocation.
5. Vibration
No electrical discontinuity of 1 µs or more.
Contact resistance: 100 m ø max.
No damage, cracks, or parts dislocation.
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 10 cycle in
each of the 3 directions.
6. Shock
No electrical discontinuity of 1 µs. min.
Contact resistance: 100 m ø max.
No damage, cracks, or parts dislocation.
Acceleration of 981 m/s2, 6ms duration, sine half-wave
waveform, 3 cycles / each of 3 axis
7. Humidity
(Steady state)
8. Temperature cycle
Contact resistance: 100 m ø max.
Insulation resistance: 50 M ø min.
No damage, cracks, or parts dislocation.
Contact resistance: 100 m ø max.
Insulation resistance: 50 M ø min.
96 hours at temperature of 40ç and humidity of 90% to 95%.RH
Temperature: -55ç / +15ç to +35ç / +85ç / +15ç to +35ç
Time: 30 / 2 to 3 / 30 / 2 to 3 (Minutes)
No damage, cracks, or parts dislocation.
5 cycles
9. Resistance to
soldering heat
No deformation of components affecting performance.
Reflow: At the recommended temperature profile
Manual soldering: 350ç±5ç for 5 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term ”storage” refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non- conducting condition of installed connectors in storage, shipment or during transportation.
Note 3: When using FPC with gold plated contact pads the connector contacts must be also gold plated : Select the (05) plating code.
sMaterials
Part
Insulator
Actuator
Contacts
Metal fittings
Material
LCP
LCP
Phosphor bronze
Phosphor bronze
Finish
Color: Black
Color: Dark brown
Tin-lead plated (Note 3)
Tin plated(No-lead)
Remarks
UL94V-0
---------------
---------------
---------------
sOrdering information
FH27- 54S - 0.4 - SH (05)
1
2
3
4
5
1 Series name: FH27
2 No. of contacts
Number of contacts: 10, 40, 54, 57, 60
3 Contact pitch: 0.4 mm
4 Terminal type
SH: SMT horizontal mounting type
5 Plating code
(05): Gold plated
(51): Tin-lead plated
2