sProduct Specifications
Rating
Current rating: 0.4A DC Operating Temperature Range:_40 to +70ç (Note 1) Storage Temperature Range:_10 to +50ç (Note 2)
Voltage rating: 50V AC Operating Humidity Range:Relative humidity, 90% max. Storage Humidity Range:Relative humidity, 90% max.
(Not dewed)
(Not dewed)
Applicable FPC
t=0.3±0.05 Tin-lead plating(Note 3) t=0.18 ± 0.05 for FH12F-*S-0.5SH
Item
1. Insulation resistance
2. Withstanding voltage
3. Contact resistance
Specification
500M ohms minimum
No flashover or insulation breakdown.
50m ohms maximum
100V DC
150V AC/1 minute
1mA
Conditions
4. Durability (Insertion/withdrawal)
Contact resistance: 50m ohms maximum
No damage, cracks, or parts dislocation.
20 cycles
5. Vibration
No electrical discontinuity of 1µs or more
Contact resistance: 50m ohms maximum.
No damage, cracks, or parts dislocation.
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours in each of the 3 directions.
6. Shock
No electrical discontinuity of 1µs or more
Contact resistance: 50m ohms maximum.
No damage, cracks, or parts dislocation.
Acceleration of 490 m/s2, 11 ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis.
Contact resistance: 50m ohms maximum.
7. Humidity(Steady state) Insulation resistance: 50M ohms minimum.
No damage, cracks, or parts dislocation.
96 hours at temperature of 40ç and humidity of 90% to 95%
8. Temperature Cycle
Contact resistance: 50m ohms maximum.
Insulation resistance: 50M ohms minimum.
No damage, cracks, or parts dislocation.
5 cycles under conditions as follows;
Temperature: -40ç / 15 to 35ç / 85ç / 15 to 35ç,
Time: 30 / 5 max. / 30 / 5 max.(minutes)
9.Resistance to Soldering heat No deformation of
components affecting performance.
Reflow: At the recommended temperature profile
Manual soldering: 350±5ç for 3 seconds
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers nonconducting condition of installed connectors in storage, shipment or during transportation.
Note 3: When FPC is gold plated, the connector contacts should be also gold plated: Select the (05) specification.
sMaterial
Part
Insulator
Contact
Macal Fittings
Material
Polyamide
PPS
Phosphor bronze
Brass
Finish
Color : Beige
Color : Dark brown
Tin-lead plating
Tin-lead plating
Remarks
UL94V-0
–––––––
sOrdering Information
FH12 A - 10 (4) - S A - 0.5 SH (05)
q
w
er
ty
u
i
o
q Series Name : FH12
t Contact alignment: Single
w Blank : standard type
y Eccentric direction:
A : Top contact type
Blank : standard type
S : Type with strengthed flip-lock actuator
A : Eccentric type
F : Type with 0.18mm FPC End Thickness
u Contacts Pitch : 0.5mm, 1mm
e Standard type : Number of contacts
i Contact type
Eccentric type : Number of contacts in 0.5mm housing SH : SMT horizontal mounting type
r Standard type : Blank
SV : SMT vertical mounting type
Eccentric type : Number of contacts
o Plating specification
Blank : Tin-lead plating
(05) : Gold plating