sPrecautions (mating/un-mating FPC with the retention tabs)
Operation
Precautions
1.How to insert
Insert the cable into the interspace between the
mold walls ( ) at both ends of entrance where
the connector is inserted and the guide walls ( )
at both ends of interior connector so the cable tabs
are properly located.
2 Avoid “ride on”
Avoid insertion so the cables ride on any guide. Be
sure NOT to close the actuator as the cables ride
on any guide. It may cause conduction failure.
Ride on a left guide
Ride on a right guide
2.Precautions when mating /un-mating
1 Avoid insertion in diagonal direction.
Do not insert the cable in diagonal direction.
A part of the connector may touches the contacts
resulting in deformation of the contacts.
Correct insertion
Do not close the actuator
as the cables ride on.
Insert the cable straight into the connector and
hook the cable tabs with the guide.
After insertion, slightly pull the cables to make sure
the cable tabs are firmly secured. No removal of the
cable means correct insertion.
1 Insert the cable
straight and obliquely
from above.
2 Slightly pull the cable
to make sure the tabs
are firmly secured.
In the event it is locked as the cables ride on a
guide, absolutely avoid moving the cable. In this
case, open the actuator and re-insert the cable as
instructed in “1.How to insert”.
Do not move the cables back and forth and around as the
cables ride on the guide when the actuator is closed.
3 $MPTFUIFBDUVBUPS
11