English
Language : 

FH28 Datasheet, PDF (10/11 Pages) Hirose Electric – 0.5 mm Pitch, 2.55 mm above the board, Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
FH28 Seriesq0.5 mm Pitch, 2.55 mm above the board, Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
sOperation and Precautions
Operation
1.FPC/FFC insertion procedure.
Connector installed on the board.
1 Lift up the actuator. Use thumb or index finger
Precautions
1 Do not force the actuator to open beyond its fully open
position. Do not use any type of tool to open the actuator.
116°
2 Fully insert the FPC in the connector parallel to
mounting surface, with the exposed conductive
traces facing down.
2 Properly insert the FPC at the positioning part of the connector.
Locking the FPC while it is partially inserted, may cause lock
damage, disconnection of the FPC, or continuity fault.
3 Do not forcefully bend the FFC/FPC upward.
Consult FFC/FPC manufacturer for the
recommended bend radiuses.
3 Rotate down the actuator until firmly closed. It is
critical that the inserted FPC/FFC is not moved and
remains fully inserted.
4 For connectors with multiple contacts, such as 80
pos. rotate down the actuator pushing at both ends.
2.FPC/FFC removal
Fully open the actuator.
Carefully withdraw the FPC/FFC exercising caution
not to deform or damage it.
5 Application of excessive force to the inserted FPC/FFC may cause damage to
connector and may affect the reliability of electrical connection.
If specific application requires continuous or repeated pull or bend of the inserted
FPC/FFC, assure that the forces are NOT transmitted directly to the connector.
10