English
Language : 

S11106-10_15 Datasheet, PDF (2/12 Pages) Hamamatsu Corporation – CMOS linear image sensors
CMOS linear image sensors
S11106-10, S11107-10
Recommended terminal voltage (Ta=25 °C)
Parameter
Supply voltage
Clock pulse voltage
High level
Low level
Start pulse voltage
High level
Low level
Symbol
Min.
Vdd
3.0
V(CLK)
3.0
0
3.0
V(ST)
0
Typ.
Max.
Unit
-
5.25
V
Vdd
Vdd + 0.25
V
-
0.4
V
Vdd
Vdd + 0.25
V
-
0.4
V
Electrical characterisitics (Ta=25 °C)
Parameter
S11106-10
S11107-10
Symbol
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Clock pulse frequency
f(CLK)
5k
-
10 M
5k
-
10 M
Hz
Video data rate
VR
-
f(CLK)
-
-
f(CLK)
-
Hz
Output impedance
Zo
60
-
140
60
-
140
Ω
Current consumption*3 Vdd=3 V
Vdd=5 V
4.0
6.0
8.0
2.5
4.5
6.5
I
mA
7.0
9.0
11.0
4.5
6.5
8.5
*3: f(CLK)=10 MHz, dark state, V(CLK)=V(ST)=Vdd
Electrical and optical characteristics [Ta=25 °C, Vdd=3 V/5 V, V(CLK)=V(ST)=Vdd, f(CLK)=10 MHz]
Parameter
Symbol
S11106-10
S11107-10
Unit
Min.
Typ.
Max.
Min.
Typ.
Max.
Spectral response range
λ
400 to 1000
400 to 1000
nm
Peak sensitivity wavelength
λp
-
700
-
700
-
nm
Photosensitivity*4
Conversion efficiency*5
S
-
80
-
CE
-
0.75
-
-
75
-
V/(lx · s)
-
0.35
-
μV/e-
Output offset voltage
Vo
0.5
0.8
1.1
0.5
0.8
1.1
V
Dark output voltage*6
Vd
-
0.02
0.2
-
0.04
0.4
mV
Saturation output voltage*7 Vdd=3 V
Vdd=5 V
1.8
2.0
2.2
1.8
2.0
2.2
Vsat
3.7
4.0
4.3
3.7
4.0
4.3
V
Readout noise*8
Vdd=3 V
Vdd=5 V
Nr
-
1.0
1.5
-
0.9
1.5
mV rms
-
0.7
1.2
-
0.6
1.1
Dynamic range 1*9
Vdd=3 V
Vdd=5 V
DR1
-
2000
-
-
5700
-
-
2200
-
-
6600
-
times
Dynamic range 2*10
Vdd=3 V
Vdd=5 V
-
100000
-
DR2
-
200000
-
-
50000
-
-
100000
-
times
Photoresponse nonuniformity*4 *11
PRNU
-
±2
±10
-
±2
±10
%
*4: Measured with a 2856 K tungsten lamp
*5: Output voltage generated per one electron
*6: Integration time=10 ms
*7: Voltage difference from Vo
*8: Dark state
*9: DR1 = Vsat/Nr
*10: DR2 = Vsat/Vd
*11: Photoresponse nonuniformity (PRNU) is the output nonuniformity that occurs when the entire photosensitive area is uniformly
illuminated by light which is 50% of the saturation exposure level. PRNU is measured using 112 pixels (S11106-10) excluding 8
pixels each at both ends or 56 pixels (S11107-10) excluding 4 pixels each at both ends, and is defined as follows:
PRNU = ∆X/X × 100 [%]
X: the average output of all pixels, ∆X: difference between X and maximum or minimum output
Appearance inspection standards
Parameter
Foreign matter on photosensitive area
Test criterion
10 μm max.
Inspection method
Automated camera
2