FGF506D Datasheet, PDF (2/4 Pages) Gamewell-FCI by Honeywell – Pre-action / Deluge Control Panel | |||
|
◁ |
Features (Continued)
⢠History Log with 256 event storage.
⢠Piezo sounder for alarm, trouble and supervisory.
⢠24 volt DC operation.
⢠Low AC voltage sense.
⢠Outputs Programmable for the following:
- Releasing circuits or NACs
⢠NACs programmable for the following:
- Silence Inhibit
- Auto-Silence
- Strobe Synchronization
- Selective Silence (horn-strobe mute)
- Temporal or Steady Signal
- Silenceable or Non-silenceable
- Release Stage Sounder
⢠Disable/Enable control per input zone and output zone.
⢠Extensive transient protection.
⢠Automatic battery charger with charger supervision.
⢠Optional Dress Panel DP-51050 (red).
⢠Optional Trim Ring TR-CE (red) for semi-flush
mounting the cabinet.
⢠Optional CAC-5X Class A Converter Module for
Outputs and IDCs.
⢠Optional 4XTMF Municipal Box Transmitter Module.
⢠Optional Digital Alarm Communicators (411, 411UD,
411UDAC).
Programming and Software
The programming software offers the following features:
⢠Custom English labels (per point) may be manually
entered or selected from an internal library file.
⢠Three programmable Form-C relay outputs.
⢠Pre-programmed and custom application templates.
⢠Continuous fire protection during online programming
at the front panel.
⢠Program Check automatically catches common errors
not linked to any zone or input point.
User Interface
The user interface features are listed below:
⢠Integral 80-character LCD display with backlighting.
⢠Real-time clock/calendar with automatic daylight
savings adjustments.
⢠ANN-Bus for connection to remote annunciators.
⢠Audible or silent walk test capabilities.
⢠Piezo sounder for alarm, trouble, and supervisory.
Controls and Indicators
The panel provides the following LED Indicators:
⢠Fire Alarm (red)
⢠AC Power (green)
⢠Supervisory (yellow) ⢠Alarm Silenced (yellow)
⢠Trouble (yellow)
⢠Discharge (red)
Control Buttons
⢠Acknowledge
⢠Alarm Silence
⢠System Reset (lamp test)
⢠Drill
Features (Continued)
AC Power â TB1
The AC Power -TB1 for each panel is listed below:
⢠GF506D:
120 VAC, 50/60 Hz, 2.3 amps
⢠Wire size: minimum #14 AWG (2.0 mm2) with 600V
insulation.
⢠Supervised, non power-limited
Battery (sealed lead acid only) â J12:
The Battery (for sealed lead acid only) - J12 specifications
are listed below.
⢠Maximum Charging Circuit - Normal Flat Charge:
- 27.6 VDC @ 1.4 amp. Supervised, non power-limited.
⢠Maximum Charger Capacity:
- 26 Amp Hour battery (two 18 Amp Hour batteries can
be housed in the FACP cabinet. Larger batteries
require separate battery box such as the BB-26 or
BB-55).
⢠Minimum Battery Size: 7 Amp Hour
Initiating Device Circuits - TB4 and TB6
The Initiating Device Circuits for TB4 and TB6
specifications are listed below.
⢠Alarm Zones 1 - 5 on TB4
⢠Alarm Zone 6 on TB6
⢠Supervised and power-limited circuitry
⢠Style B (Class B) wiring with Style D (Class A) option
⢠Normal Operating
Voltage:
Nominal 20 VDC
⢠Alarm Current:
15 mA minimum
⢠Short Circuit Current: 40 mA max
⢠Maximum Loop
Resistance:
100 Ohms
⢠End-of-Line Resistor: 4.7KOhms, 1/2 watt
(PN 71252)
⢠Standby Current:
4 mA
For a list of compatible devices, refer to the Gamewell-FCI
Device Compatibility Document, P/N: 52195.
Notification Appliance and Releasing Circuit(s) -
TB5 and TB7
The notification appliance and releasing circuits for TB5
and TB7 specifications are listed below.
⢠Four Output Circuits.
⢠Style Y (Class B) or Style Z (Class A) with optional
converter module
⢠Strobe synchronization
⢠Special Application power
⢠Supervised and power-limited circuitry
⢠Normal Operating
Voltage:
Nominal 24 VDC
⢠Maximum Signaling
Current:
7.0 amps (3.0 amps
maximum per NAC)
⢠End-of-Line Resistor: 4.7KOhms, 1/2 watt
(PN71252)
⢠Max. Wiring Voltage
Drop:
2 VDC
For a list of compatible devices, refer to the Gamewell-FCI
Device Compatibility Document, P/N: 52195.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA ⢠Tel: (203) 484-7161 ⢠Fax: (203) 484-7118
9021-60466 Rev. D page 2 of 4