MB39A106 Datasheet, PDF (6/46 Pages) Fujitsu Component Limited. – 2-Channel DC/DC Converter IC with Overcurrent Protection Symmetrical-Phase Type
MB39A106
■ RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Condition
Value
Unit
Min
Typ
Max
Power-supply voltage
VCC
⎯
Boot voltage
VCB CB terminal
Reference voltage output current IOR VREF terminal
Bias output current
IOB VB terminal
VIN −INE terminal
Input voltage
CTL1, CTL2 terminal
VCTL
CTL terminal
Output voltage
VPG PWRGOOD terminal
Output current
IO
⎯
Peak output current
IOP
Duty ≤ 5%
(t = 1 / fOSC × Duty)
Oscillation frequency
fOSC
⎯
Timing resistor
RT
⎯
Boot capacitor
CB
⎯
6.5
⎯
−1
−1
0
0
0
0
− 100
− 700
100
30
⎯
12
18
V
⎯
24
V
⎯
0
mA
⎯
0
mA
⎯
VCC − 1.8 V
⎯
VREF
V
⎯
VCC
V
⎯
15
V
⎯
+100
mA
⎯
+700
mA
300
500
kHz
47
130
kΩ
0.1
1.0
µF
Reference voltage output
capacitor
CREF VREF terminal
⎯
0.1
1.0
µF
Bias output capacitor
Soft-start capacitor
Short-circuit detection capacitor
CVB
CS
CSCP
VB terminal
⎯
⎯
1.0
4.7
10
µF
⎯
0.1
1
µF
⎯
0.01
1
µF
Overcurrent detection setting
resistor
RLIM
⎯
0.1
1
10
kΩ
Operating ambient temperature Ta
⎯
− 30
+ 25
+ 85
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.