MB39A106 Datasheet, PDF (15/46 Pages) Fujitsu Component Limited. – 2-Channel DC/DC Converter IC with Overcurrent Protection Symmetrical-Phase Type | |||
|
◁ |
MB39A106
(4) Timer-latch overvoltage protection circuit block (OVP)
When the overvoltage detection comparator (OVP Comp.) provided for each channel detects the DC/DC con-
verterâs output voltage level exceeding its threshold voltage, the timer-latch overvoltage protection circuit actuates
the timer circuit and starts charging the capacitor CSCP connected to the CSCP terminal (pin 11). If the overvoltage
remains applied beyond the predetermined period of time, the circuit sets the latch to turn off the FET on the
main side of each channel while setting the PWRGOOD terminal (pin 12) to the âLâ level.
To reset the actuated protection circuit, either the power supply turn off and on again or set the CTL terminal
(pin 6) to the âLâ level to lower the VREF terminal (pin 8) voltage to 1.7 V (Min) or less. It can also be reset by
setting both of the CTL1 terminal (pin 9) and CTL2 terminal (pin 10) to the âLâ level. (Refer to â3. Setting
Overvoltage Detection by the Timer-Latch Overvoltage Protection Circuitâ in â ABOUT TIMER-LATCH PRO-
TECTION CIRCUIT.)
(5) Protection status output circuit block (PWRGOOD)
The protection status output circuit outputs the âLâ level signal to the PWRGOOD terminal (pin 12) when each
protection circuit is actuated.
15
|
▷ |