English
Language : 

MB15E07SR Datasheet, PDF (6/25 Pages) Fujitsu Component Limited. – Single Serial Input PLL Frequency Synthesizer On-chip 2.5 GHz Prescaler
MB15E07SR
■ ELECTRICAL CHARACTERISTICS
(VCC = 2.7 V to 5.0 V, Ta = –40°C to +85°C)
Parameter
Sym-
bol
Condition
Value
Unit
Min
Typ Max
Power supply current*1
ICC*1 fIN = 2500 MHz, VCC = VP = 3.75 V
–
Power saving current
IPS PS = “L”
–
fin
fIN 50 Ω system
100
Operating frequency
OSCIN OSCIN
–
3
8.0
0.1*2
–
–
–
20
2500
40
mA
µA
MHz
MHz
Input sensitivity
100 MHz to 300 MHz
fin*3 Pfin
300 MHz to 2500 MHz
–6
–
+2 dBm
–15
–
+2 dBm
“H” level input voltage
“L” level input voltage
OSCIN*3
Data,
Clock,
LE, PS
VOSC
VIH
VIL
–
0.5
–
VCC Vp-p
–
VCC × 0.7 –
–
V
–
–
– VCC × 0.3
“H” level input current Data, IIH*4
–
–1.0
–
+1.0
Clock,
µA
“L” level input current LE, PS IIL*4
–
–1.0
–
+1.0
“H” level input current
IIH
–
0
–
+100
OSCIN
µA
“L” level input current
IIL*4
–
–100
–
0
“H” level output voltage
VOH VCC = VP = 3.75 V, IOH = –1 mA VCC – 0.4 –
LD/fout
“L” level output voltage
VOL VCC = VP = 3.75 V, IOL = 1 mA
–
–
“H” level output voltage
VDOH VCC = VP = 3.75 V, IDOH = –0.5 mA VP – 0.4
–
Do
“L” level output voltage
VDOL VCC = VP = 3.75 V, IDOL = 0.5 mA
–
–
–
V
0.4
–
V
0.4
High impedance cutoff
current
Do
“H” level output current
LD/fout
“L” level output current
“H” level output current
Do
“L” level output current
IOFF
IOH
IOL
IDOH*4
IDOL
VCC = VP = 3.75 V,
VOFF = 0.5 V to VP – 0.5 V
–
–
VCC = 3.75 V,
VP = 3.75 V,
VDO = VP/2
Ta = +25°C
CS bit = “1”
CS bit = “0”
CS bit = “1”
CS bit = “0”
–
–
2.5 nA
–
–
–1.0
mA
1.0
–
–
–
–4.0
–
–
–1.0
–
mA
–
4.0
–
–
1.0
–
Charge pump current
rate
IDOL/IDOH IDOMT*5 VDO = VP/2
vs VDO IDOVD*6 0.5 V ≤ VDO ≤ VP – 0.7 V
vs Ta IDOTA*7 – 40°C ≤ Ta ≤ +85°C
–
5
–
%
–
10
–
%
–
3
–
%
*1: Conditions; fosc = 13 MHz, Vosc = 1.2 VPP , Ta = +25°C, in locking state.
*2: VCC = VP = 3.75 V, fosc = 13 MHz, Vosc = 1.2 VPP , Ta = +25°C, in power saving mode
*3: AC coupling. 1000 pF capacitor is connected under the condition of minimum operating frequency.
*4: The symbol “–” (minus) means direction of current flow.
*5: VCC = VP = 3.0 V, Ta = +25°C
(||I3| – |I4||) / [(|I3| + |I4|) /2] × 100(%)
(Continued)
6