5. Power-Save Mode
This section describes the setting methods and states.
(1) Mode setting
Power-save mode can be controlled by an external control signal and register setting.
The various modes set each block to a power-save state, enabling the power consumption to be reduced.
• Power-save mode setting table
Mode
Address
PS
or 00100 00101 00110
10000
10001
SYNC
or
CLK
Address
10111
D4 D0 D4 D2 D1 D0 D4 D3 D2 D1 D4 D2 D1 D0 STOP
Reception
All PD
0 –– – ––––––––––– –
VREF
operation
1 –– – –––––0––––– –
SGO PD
1 –– – –––––1––––– –
TONE
operation
1 –– – ––––0–––––– –
CODEC,
TONE PD
1 –– – –––11–––––– –
CODEC
operation
1 –– – –––0–––––––
CODEC
SYNC PD
1 –– – –––0–––––––
Transmission
operation
1
–– – ––––––0––––
–
Transmission
PD
1
–– – ––––––1––––
–
1 1– 1 11101––0100 –
Reception
operation
1 0– 1 11001––0100 –
1 0– 1 10101––0001 –
1 1– 0 00001––1100 –
1 0– 1 11101––1111 –
––––––––
––––––––
–––
––––
––
–– – ––––
–– – ––––
–
–––––––
–
–––––––
–– –
–– –
–– –
–– –
–– –
: Operation enabled, : Changes depending on address 10001, : Power-down
Note: Powering down the CODEC or TONE generator powers down the entire reception block.