English
Language : 

MB39C007 Datasheet, PDF (12/52 Pages) Fujitsu Component Limited. – 2 ch DC/DC Converter IC Built-in Switching FET & voltage detection function, PFM/PWM Synchronous Rectification, and Down Conversion Support
MB39C007
(Continued)
(Ta = +25 °C, AVDD = DVDD1 = DVDD2 = 3.7 V, VOUT1/VOUT2 setting value = 2.5 V, MODE1/MODE2 = 0 V)
Parameter
Symbol Pin No.
Condition
Value
Unit
Min Typ Max
Control
block
CTL threshold
voltage
CTL pin
input current
VTHHCT
VTHLCT
IICTL
1, 2, 3
⎯
⎯
0 V ≤ CTLP/CTL1/CTL2 ≤
3.7 V
0.55 0.95 1.45 V
0.40 0.80 1.30 V
⎯
⎯
1.0 μA
Reference VREF voltage
voltage
block
VREF Load
stability
VREF
LOADREF
VREF = 0 A
6
VREF = −1.0 mA
1.274 1.300 1.326 V
⎯
⎯
20 mV
Shut down
power supply
current
IVDD1
IVDD1H
CTLP/CTL1/CTL2 = 0 V,
State of all circuits OFF*3
CTLP/CTL1/CTL2 = 0 V,
VDD = 5.5 V,
State of all circuits OFF*3
⎯
⎯
1.0 μA
⎯
⎯
1.0 μA
Power supply
current at DC/DC
operation 1
(PFM mode)
IVDD21
IVDD22
1. CTLP = 0 V,CTL1 = 3.7 V,
CTL2 = 0 V
2. CTLP = 0 V, CTL1 = 0 V,
⎯
30
48 μA
CTL2 = 3.7 V, OUT = 0 A
CTLP = 0 V, CTL1/CTL2 =
3.7 V, OUT = 0 A
⎯ 50 80 μA
General
1. CTLP = 0 V, CTL1 = 3.7 V,
CTL2 = 0 V, MODE1/
5, 11,
MODE2 = OPEN
Power supply
current at DC/DC
IVDD31
12, 19, 2. CTLP = 0 V, CTL1 = 0 V,
20
CTL2 = 3.7 V, MODE1/
MODE2 = OPEN,
⎯
operation 2
OUT = 0 A
(PWM mode)
CTLP = 0 V, CTL1/CTL2 =
IVDD32
3.7 V,
MODE1/MODE2 = OPEN,
⎯
OUT = 0 A
3.5 10.0 mA
7.0 20.0 mA
Power supply
current
(voltage detection
IVDD5
mode)
CTLP = 3.7 V,
CTL1/CTL2 = 0 V
⎯ 15 24 μA
Power-on
invalid current
IVDD
1. CTL1 = 3.7 V, CTL2 = 0 V
2. CTL1 = 0 V, CTL2 = 3.7 V,
VOUT1/VOUT2 = 90%,
⎯
OUT = 0 A*4
1000 2000 μA
*1 : The minimum value of AVDD = DVDD1 = DVDD2 is the 2.5 V or VOUT setting value + 0.6 V, whichever is higher.
*2 : The + leak at the LX pin includes the current of the internal circuit.
*3 : Sum of the current flowing into the AVDD, the DVDD1, and the DVDD2 pins.
*4 : Current consumption based on 100% ON-duty (High side FET in full ON state). The SW FET gate drive current is
not included because the device is in full ON state (no switching operation). Also the load current is not included.