English
Language : 

33810_10 Datasheet, PDF (30/35 Pages) Freescale Semiconductor, Inc – Automotive Engine Control IC
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
Table 21. SPI Response Messages
Address <0101>
Reset COR OVER under X X X X X X X X X X
End Spark filter Register
Voltage voltage
End spark
Filter
Address <1010>
Reset COR OVER LOW MAXI DAC Threshold
DAC Command Register
Voltage Voltage
Overlap Setting
NOMI DAC Threshold
Address <1011>
Reset
GPGD FBx Short to
Battery Threshold Voltage
Register
COR
OVER LOW
Voltage Voltage
Short to Batt VFB3
Short to Batt VFB2
Short to Batt VFB1
Short to Batt VFB0
Address <1100>
GPGD FBx Short to
Battery Threshold Timer
Register
Reset COR OVER LOW
Voltage Voltage
Short to Batt tFB3
Short to Batt tFB2
Short to Batt tFB1
Short to Batt tFB0
Address <1101>
GPGD Fault Operation
Register
Reset COR OVER LOW
Voltage Voltage
Retry/Shutdown Bit
X X X X Shutdown Drivers on IMAX
Address <1110>
PWM Freq&DC Register
(last channel
programmed)
Reset COR OVER LOW
Voltage Voltage
PWMx
address
PWM Frequency
PWM Duty Cycle
Address <1111>
Reset COR OVR LOW
REV ID
CAL CAL
TRIM TRIM
Revision ID, Trim, Clock
Cal.
Vtg Voltage 3
2
1
0
X
X Too Too X
X Parity Lock
HI LOW
Error Out
Legend
COR = Command Out of Range
SOR = Supply Out of Range
NMF = Set When Faults Occur on V10 Mode MAXI and NOMI Inputs and V10 Mode Ignition Driver are OFF.
33810
30
Analog Integrated Circuit Device Data
Freescale Semiconductor