English
Language : 

33810_10 Datasheet, PDF (25/35 Pages) Freescale Semiconductor, Inc – Automotive Engine Control IC
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
Bank 1 Bank 2
IC 1 “Parent”
IC 3 “Child”
GIN0
GO0
Gate Drive 0
GIN1
GO1
Gate Drive 1
GIN2
GO2
Gate Drive 2
GIN3
GO3
Gate Drive 3
4
GIN (0-3)
NOMI
LOGIC
MAXI RSP1
VtNI
NOMI
Comparator
VtMI
MAXI
Comparator
IGBT1 (0-3) IGBT14
IGBT15
GO0
GIN0
Gate Drive 0
GIN1
GO1
Gate Drive 1
GO2
GIN2
Gate Drive 2
GIN3
GO3
Gate Drive 3
4 GIN
(0-3)
RSP
LOGIC
NOMI
MAXI
IGBT26
IGBT 2 (0-3)
IGBT27
RS1
Ign 1
Child
Comparator
Inputs Tied
to GND
VtNI NOMI
disabled
VtMI
MAXI
disabled
Ign 2
RS2
Logic
Buffer
Logic
Buffer
Logic
Buffer
Logic
Buffer
IC 2 “Parent”
GO0
GIN0
GO1
GIN1
GO2
GIN2
GO3
GIN3
4 GIN (0-3)
LOGIC
MAXI
RSP2
NOMI
VtNI
NOMI
Comparator
VtMI
MAXI
Comparator
Logic
Buffer
Logic
Buffer
NOMI MAXI
NOMI1 to uP
MAXI1 to uP
MAXI2 to uP
MAXI
NOMI
MAXI NOMI
NOMI2 to uP
Note: For “child” input NOMI is for channel 1&3, input MAXI is for channel 0&2
Figure 10. V10 Mode
LOW SIDE INJECTOR DRIVER
The four open drain low side injector drivers are designed
to control various automotive loads such as injectors,
solenoids, lamps, relays and unipolar stepper motors. Each
driver includes off and on state open load detection, short
circuit protection and diagnostics. The injector drivers are
individually controlled through the ON/OFF SPI input
command Table 20 or parallel input pins DIN0 to DIN3. Serial
and parallel control of the output state is determined by the
logical OR of the SPI serial bit and the DINx parallel input
pins. All four outputs are disabled when the OUTEN input pin
is high regardless of the state of the SPI control bit or the
state of the DINx pin. All four injector drivers are not affected
by the selection of the gate driver’s three modes of operation
(Ignition Mode, General Purpose Mode, V10 mode).
ON /OFF CONTROL COMMAND
To program the individual output of the 33810 ON or OFF,
a 16-bit serial stream of data is entered into the SI pin. The
first 4 bits of the control word are used to identify the On / Off
Command. Bit 0 through bit 3 of the ON/OFF Control
Command turn ON or OFF the specific output driver.
INJECTOR DRIVER FAULT COMMANDS
Fault protection strategies for the injector drivers are
programmed by the SPI LSD Fault Command. Bit 8 through
11 determine the type of short circuit protection to be used,
bits 0 through 7 set the open load strategy.
Short-circuit protection consists of three strategies. All
strategies utilize current limiting as an active element to
protect the output driver from failure.The TLIM and Timer
options are used to enhance the short circuit protection
strategy of the Injector drivers. The timer protection scheme
uses a low duty cycle in the event of a short-circuit. The TLIM
Analog Integrated Circuit Device Data
Freescale Semiconductor
33810
25