MC68HC908QY4A_10 Datasheet, PDF (148/200 Pages) Freescale Semiconductor, Inc – M68HC08 Microcontrollers
Development Support
Table 15-1. Monitor Mode Signal Requirements and Options
Mode
Serial
Communi-
IRQ RST Reset cation
(PTA2) (PTA3) Vector
Mode
Selection
PTA0 PTA1 PTA4
COP
Communication
Speed
External Bus
Baud
Clock Frequency Rate
Comments
Normal
Monitor
VTST
VDD
X
1
1
0
Disabled
9.8304
MHz
2.4576
MHz
9600
Provide external
clock at OSC1.
Forced VDD
X
$FFFF
(blank)
1
Monitor
VSS
X
$FFFF
(blank)
1
X
X
Disabled
9.8304
MHz
2.4576
MHz
9600
Provide external
clock at OSC1.
X
X Disabled X
3.2 MHz
(Trimmed)
9600
Internal clock is
active.
User
X
X
Not
$FFFF
X
X
X Enabled
X
X
X
MON08
Function
[Pin No.]
VTST
[6]
RST
[4]
—
COM MOD0 MOD1
[8]
[12] [10]
—
OSC1
[13]
—
—
1. PTA0 must have a pullup resistor to VDD in monitor mode.
2. Communication speed in the table is an example to obtain a baud rate of 9600. Baud rate using external oscillator is bus
frequency / 256 and baud rate using internal oscillator is bus frequency / 335.
3. External clock is a 9.8304 MHz oscillator on OSC1.
4. Lowering VTST once monitor mode is entered allows the clock source to be controlled by the OSCSC register.
5. X = don’t care
6. MON08 pin refers to P&E Microcomputer Systems’ MON08-Cyclone 2 by 8-pin connector.
NC 1
NC 3
NC 5
NC 7
NC 9
NC 11
OSC1 13
VDD 15
2 GND
4 RST
6 IRQ
8 PTA0
10 PTA4
12 PTA1
14 NC
16 NC
15.3.1.1 Normal Monitor Mode
RST and OSC1 functions will be active on the PTA3 and PTA5 pins respectively as long as VTST is
applied to the IRQ pin. If the IRQ pin is lowered (no longer VTST) then the chip will still be operating in
monitor mode, but the pin functions will be determined by the settings in the configuration registers (see
Chapter 5 Configuration Register (CONFIG)) when VTST was lowered. With VTST lowered, the BIH and
BIL instructions will read the IRQ pin state only if IRQEN is set in the CONFIG2 register.
If monitor mode was entered with VTST on IRQ, then the COP is disabled as long as VTST is applied to
IRQ.
15.3.1.2 Forced Monitor Mode
If entering monitor mode without high voltage on IRQ, then startup port pin requirements and conditions,
(PTA1/PTA4) are not in effect. This is to reduce circuit requirements when performing in-circuit
programming.
MC68HC908QYA/QTA Family Data Sheet, Rev. 3
148
Freescale Semiconductor