English
Language : 

K30P81M100SF2_11 Datasheet, PDF (11/62 Pages) Freescale Semiconductor, Inc – Up to 100 MHz ARM Cortex-M4 core with DSP instructions delivering 1.25 Dhrystone MIPS per MHz
General
1. All functional non-supply pins are internally clamped to VSS, and induce an injection current when VIN is less than VSS. The
IIC maximum operating requirement should not be exceeded. If this requirement cannot be met, the input must be current
limited to the value specified.
5.1.2 LVD and POR operating requirements
Table 2. VDD supply LVD and POR operating requirements
Symbol Description
Min.
Typ.
Max.
Unit
VPOR
VLVDH
Falling VDD POR detect voltage
Falling low-voltage detect threshold — high
range (LVDV=01)
TBD
1.1
TBD
V
TBD
2.56
TBD
V
Low-voltage warning thresholds — high range
VLVW1H
VLVW2H
VLVW3H
VLVW4H
• Level 1 falling (LVWV=00)
• Level 2 falling (LVWV=01)
• Level 3 falling (LVWV=10)
• Level 4 falling (LVWV=11)
TBD
2.70
TBD
V
TBD
2.80
TBD
V
TBD
2.90
TBD
V
TBD
3.00
TBD
V
VHYSH Low-voltage inhibit reset/recover hysteresis —
60
mV
high range
VLVDL Falling low-voltage detect threshold — low range TBD
1.60
TBD
V
(LVDV=00)
Low-voltage warning thresholds — low range
VLVW1L
VLVW2L
VLVW3L
VLVW4L
• Level 1 falling (LVWV=00)
• Level 2 falling (LVWV=01)
• Level 3 falling (LVWV=10)
• Level 4 falling (LVWV=11)
TBD
1.80
TBD
V
TBD
1.90
TBD
V
TBD
2.00
TBD
V
TBD
2.10
TBD
V
VHYSL Low-voltage inhibit reset/recover hysteresis —
40
mV
low range
VBG Bandgap voltage reference
tLPO Internal low power oscillator period
factory trimmed
TBD
1.00
TBD
V
TBD
1000
TBD
μs
1. Rising thresholds are falling threshold + hysteresis voltage
Table 3. VBAT power operating requirements
Symbol Description
VPOR_VBAT Falling VBAT supply POR detect voltage
Min.
Typ.
Max.
Unit
TBD
1.1
TBD
V
Notes
1
1
Notes
K30 Sub-Family Data Sheet Data Sheet, Rev. 4, 3/2011.
Freescale Semiconductor, Inc.
Preliminary