56F8356 Datasheet, PDF (100/176 Pages) Motorola, Inc – 56F8356 16-bit Hybrid Controller
• 11 = IRQ is priority level 2
5.6.10.5 ADC A Zero Crossing or Limit Error Interrupt Priority Level
ADCA_ZC IPL)—Bits 7–6
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.6.10.6 ADC B Zero Crossing or Limit Error Interrupt Priority Level
(ADCB_ZC IPL)—Bits 5–4
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.6.10.7 ADC A Conversion Complete Interrupt Priority Level
(ADCA_CC IPL)—Bits 3–2
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2
5.6.10.8 ADC B Conversion Complete Interrupt Priority Level
(ADCB_CC IPL)—Bits 1–0
This field is used to set the interrupt priority level for IRQs. This IRQ is limited to priorities 0 through 2.
They are disabled by default.
• 00 = IRQ disabled (default)
• 01 = IRQ is priority level 0
• 10 = IRQ is priority level 1
• 11 = IRQ is priority level 2