English
Language : 

XRP9710 Datasheet, PDF (28/36 Pages) Exar Corporation – Dual 6A Programmable Power Module
XRP9710 and XRP9711
Dual 6A Programmable Power Module
by the following equation where the range for
N is 1 to 63:
𝑁 ∗ 𝐿𝑆𝐵(𝑚𝑉) ∗ 105
𝑂𝑉𝑃(%) = 𝑉𝑡𝑎𝑟𝑔𝑒𝑡 (𝑉)
When the OVP level is reached and the fault is
generated, the host will be notified by the
SUPPLY_FAULT_EVENT interrupt generated by
the controller. The host then can use an I2C
command to check which channel is at fault.
In addition, OVP fault can be monitored
through GPIO0.
A user can choose one of three options in
response to an OVP event: shutdown the
faulting channel, shut down faulting channel
and perform auto-restart of the channel, or
restart the chip.
Note: The Channel Fault Action response is
the same for an OVP or OCP event.
OCP
A user defined OCP fault level is set with 10
mA increments in PA 5.1. PA 5.1 uses
calculations to give the user the approximate
DC output current entered in the current limit
field. However the actual current limit trip
value programmed into the part is limited to
280mV as defined in the electrical
characteristics. The maximum value the user
can program is limited by Rdson of the
synchronous Power FET and current
monitoring ADC range. For example, using a
synchronous FET with RDSON of 30mΩ, and the
wider ADC range, the maximum current limit
programmed would be:
In the case of shutting down the faulting
channel and auto-restarting, the user has an
option to specify startup timeout (the time in
which the fault is validated) and hiccup
timeout (the period after which the controller
will try to restart the channel) periods in 1
msec increments with a maximum value of
255 msec.
280𝑚𝑉
𝑂𝐶𝑃 𝑀𝑎𝑥(𝐴) = 30𝑚Ω = 9.33𝐴
The current is sampled approximately 30ns
before the low side MOSFET turns off, so the
actual measured DC output current in this
example would be 9.33A plus approximately
half the inductor ripple.
An OCP Fault is considered to have occurred
only if the fault threshold has been tripped in
four consecutive switching cycles. When the
switching frequency is set to the 4x multiplier,
the current is sampled only every other cycle.
As a result it can take as many as eight
switching cycles for an over current event to
© 2014 Exar Corporation
28/36
Rev. 1.0.1