English
Language : 

XRT75L06D Datasheet, PDF (13/103 Pages) Exar Corporation – SIX CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCHRONIZER
xr
XRT75L06D
REV. 1.0.4
SIX CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCHRONIZER
CONTROL AND ALARM INTERFACE
LEAD #
B7
R6
C14
R14
C6
D14
B8
R7
C13
R13
C7
D13
C5
T4
B12
T12
D5
B15
SIGNAL NAME TYP
E
DESCRIPTION
MRING_0
MRING_1
MRING_2
MRING_3
MRING_4
MRING_5
I Monitor Ring Input - Channel 0:
Monitor Ring Input - Channel 1:
Monitor Ring Input - Channel 2:
Monitor Ring Input - Channel 3:
Monitor Ring Input - Channel 4:
Monitor Ring Input - Channel 5:
The bipolar line output signal from TRING_n is connected to this pin via a 270 Ω
resistor to check for line driver failure.
NOTE: This pin is internally pulled up.
MTIP_0
MTIP_1
MTIP_2
MTIP_3
MTIP_4
MTIP_5
I Monitor Tip Input - Channel 0:
Monitor Tip Input - Channel 1:
Monitor Tip Input - Channel 2:
Monitor Tip Input - Channel 3:
Monitor Tip Input - Channel 4:
Monitor Tip Input - Channel 5:
The bipolar line output signal from TTIP_n is connected to this pin via a 270-
ohm resistor to check for line driver failure.
NOTE: This pin is internally pulled up.
DMO_0
DMO_1
DMO_2
DMO_3
DMO_4
DMO_5
O Drive Monitor Output - Channel 0:
Drive Monitor Output - Channel 1:
Drive Monitor Output - Channel 2:
Drive Monitor Output - Channel 3:
Drive Monitor Output - Channel 4:
Drive Monitor Output - Channel 5:
If MTIP_n and MRING_n has no transition pulse for 128 ± 32 TxCLK_n cycles,
DMO_n goes “High” to indicate the driver failure. DMO_n output stays “High”
until the next AMI signal is detected.
C8
RLOS_0
O Receive Loss of Signal - Channel 0:
T7
RLOS_1
C12
RLOS_2
T11
RLOS_3
B11
RLOS_4
R8
RLOS_5
Receive Loss of Signal - Channel 1:
Receive Loss of Signal - Channel 2:
Receive Loss of Signal - Channel 3:
Receive Loss of Signal - Channel 4:
Receive Loss of Signal - Channel 5:
This output pin toggles "High" if the receiver has detected a Loss of Signal Con-
dition.
9