M0519 Datasheet, PDF (8/69 Pages) List of Unclassifed Manufacturers – 32-bit Microcontroller | |||
|
◁ |
M0519
â Supports multiple clock sources from HCLK/2048 (default selection) and LIRC
â Window set by 6-bit counter with 11-bit prescale
â Able to wake up from Power-down or Idle mode
ï¬ Basic PWM
â 1 unit of 16-bit basic PWM, up to 2ch output
â Alternative function as input capture timer
ï¬ Enhanced PWM
â 2 units of 16-bit enhanced PWM, up to 6ch output with dead-zone control, brake and
polarity control for motor drive
â Default tri-state during any reset
ï¬ Enhanced Input Capture
â Up to 2 units of 24-bit input capture
â Each unit has 3 inputs: ECAPx_IC0, ECAPx_IC1 and ECAPx_IC2
ï¬ UART
â
â
â
â
â
â
ï¬ SPI
Up to two 16550 compatible UART devices
Programmable baud-rate generator
Buffered receiving and transmitting, each with 16 bytes FIFO
Supports flow control (TX, RX, CTS and RTS)
Supports IrDA(SIR) function
Supports RS-485
â
â
â
â
â
â
â
ï¬ I2C
Up to three sets of SPI device
Supports SPI master/slave mode
Full duplex synchronous serial data transfer
Variable length of transfer data from 8 to 32 bits
MSB or LSB first data transfer
Rx and Tx on both rising or falling edge of serial clock independently
Supports Byte Suspend mode in 32-bit transmission
â Master/Slave up to 1 Mbit/s
â Bi-directional data transfer between masters and slaves
â Multi-master bus (no central master)
â Arbitration between simultaneously transmitting masters
â Programmable clocks allow versatile rate control
â Multiple address recognition (four slave address with mask option)
ï¬ ADC
â Two A/D converters
â Each ADC with up to 8 channel, 12-bit resolution with 10-bit accuracy
â 16 result registers
â Sampling rate up to 800ksps
â Two operating modes:
ïµ Single Sampling mode: Only one specified channel can be sampled at one time.
ïµ Simultaneous Sampling mode: Allowing two ADC channels to be sampled
simultaneously.
â Two converting result digital comparators
â Conversion start by software, external pins, or linked with Timer 0~3 or PWM module
ï¬ Up to three Analog Comparators
ï¬ Up to two OPA (operational amplifier)
Nov. 02, 2016
Page 8 of 69
Rev 1.02
|
▷ |