English
Language : 

TH06 Datasheet, PDF (7/26 Pages) List of Unclassifed Manufacturers – I2C HUMIDITYAND TEMPERATURE SENSOR
Table 5. Temperature Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = –40 to +125 °C default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ Max
Unit
Operating Range
Accuracy1
Repeatability/Noise
–10 °C< tA < 85 °C
–40 < tA < 125 °C
14-bit resolution
–40
— +125
°C
— ±0.5 ±1
°C
Figure 3
— 0.01 —
13-bit resolution
12-bit resolution
— 0.02 —
— 0.04 —
°C RMS
Response Time2
τ63%
11-bit resolution
— 0.08 —
Unmounted device
—
0.7
—
s
TH06 -EB board
—
5.1
—
s
Long Term Stability
— ≤ 0.01 —
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Tel:+86-755-82973805 Fax: +86-755-82973550 Email:sales@hoperf.com http://www.hoperf.com
7