TH06 Datasheet, PDF (21/26 Pages) List of Unclassifed Manufacturers – I2C HUMIDITYAND TEMPERATURE SENSOR
5.2. Reading and Writing User Registers
There is one user register on the TH06 that allows the user to set the configuration of the TH06. The procedure
for accessing that register is described below.
The checksum byte is not supported after reading a user register.
Sequence to read a register
Slave
Read Reg
S
W
A
A
Address
Cmd
Slave
Sr
R
Address
A
Read Data NA P
Sequence to write a register
S
Slave Address
W
A
Write Reg Cmd
A
Write Data
A
P
5.3. Firmware Revision
The internal firmware revision can be read with the following I2C transaction:
Slave
S
W
A
0x84
A
Address
0xB8
Slave
A
S
Address
RA
FWREV
A NA P
5.5. Heater
The TH06 contains an integrated resistive heating element that may be used to raise the temperature of the
sensor. This element can be used to test the sensor, to drive off condensation, or to implement dew-point
measurement when the TH06 is used in conjunction with a separate temperature sensor such as another TH06
(the heater will raise the temperature of the internal temperature sensor).
The heater can be activated using HTRE, bit 2 in User Register 1. Turning on the heater will reduce the tendency
of the humidity sensor to accumulate an offset due to "memory" of sustained high humidity conditions.