English
Language : 

TH06 Datasheet, PDF (3/26 Pages) List of Unclassifed Manufacturers – I2C HUMIDITYAND TEMPERATURE SENSOR
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = –40 to 125 °C default conversion time unless otherwise noted.
Parameter
Conversion Time1
Symbol
tCONV
Test Condition
12-bit RH
11-bit RH
10-bit RH
Min
Typ
Max Unit
—
10
12
—
5.8
7
—
3.7
4.5
8-bit RH
14-bit temperature
13-bit temperature
12-bit temperature
11-bit temperature
—
2.6
3.1
ms
—
7
10.8
—
4
6.2
—
2.4
3.8
—
1.5
2.4
Powerup Time
tPU
From VDD ≥ 1.9 V to ready for a
—
conversion, 25 °C
From VDD ≥ 1.9 V to ready for a con-
—
version, full temperature range
After issuing a software reset
—
command
18
25
—
80
ms
5
15
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).
5. IDD after a user register write. Initiating any other subsequent I2C transaction on the same bus (such as the user
register read, starting an RH measurement, or traffic directed at other I2C devices) will transition the device to standby
mode.
6. Additional current consumption when HTRE bit enabled. See section “5.5. Heater” for more information
Table 3. I2C Interface Specifications1
1.9 ≤ VDD ≤ 3.6 V; TA = –40 to +125 °C unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ Max Unit
Hysteresis
SCLK Frequency2
VHYS High-to-low versus low-to- 0.05 x VDD —
high transition
fSCL
—
—
—
V
400 kHz
SCL High Time
tSKH
0.6
—
—
µs
SCL Low Time
tSKL
1.3
—
—
µs
Start Hold Time
tSTH
0.6
—
—
µs
Notes:
1. All values are referenced to VIL and/or VIH.
2. Depending on the conversion command, the TH06 may hold the master during the conversion (clock stretch). At
above 100 kHz SCL, the TH06 may also hold the master briefly for user register and device ID transactions. At the
highest I2C speed of 400 kHz the stretching will be <10 µs.
3. Pulses up to and including 50 ns will be suppressed.
Tel:+86-755-82973805 Fax: +86-755-82973550 Email:sales@hoperf.com http://www.hoperf.com
3