English
Language : 

TH06 Datasheet, PDF (16/26 Pages) List of Unclassifed Manufacturers – I2C HUMIDITYAND TEMPERATURE SENSOR
5. I2C Interface
The TH06 communicates with the host controller over a digital I2C interface. The 7-bit base slave address is
0x40.
Table 9. I2C Slave Address Byte
A6
A5
A4
A3
A2
A1
A0
R/W
1
0
0
0
0
0
0
0
Master I2C devices communicate with the TH06 using a command structure. The commands are listed in the I2C
command table10. Commands other than those documented below are undefined and should not be sent to the
device.
Table 10. I2C Command Table
Command Description
Measure Relative Humidity, Hold Master Mode
Measure Relative Humidity, No Hold Master Mode
Measure Temperature, Hold Master Mode
Measure Temperature, No Hold Master Mode
Read Temperature Value from Previous RH Measurement
Reset
Write RH/T User Register 1
Read RH/T User Register 1
Command Code
0xE5
0xF5
0xE3
0xF3
0xE0
0xFE
0xE6
0xE7
Tel:+86-755-82973805 Fax: +86-755-82973550 Email:sales@hoperf.com http://www.hoperf.com
16